Victron Venus OS v3.80
- Excess loads
- EEBus integration
- GX UI portrait mode
- GX control panel improvements
- Bluetooth range extender
- GX Bluetooth BMS readout
- EV charging station improvements
![]()
Featured products
EasySolar 24/1600/40-16 MPPT 100/50
1600VA Inverter & Charger Combo Unit
- Battery voltage 24V, inverter 1300W (3000W), charger 40A,
- MPPT solar charge controller 100V / 50A (1400W), 230V AC fuses & RCD,
- VE.Bus interface for system integration, programmable relay,
Accessories / Levy
Controll panels
System integration
Installation
Programmierung
|
|
||
|
Interface MK3-USB (VE.Bus to USB) |
||
|
Interface MK3-USB (VE.Bus to USB-C) |
Victron Energy EasySolar 24/1600/40-16 MPPT 100/50
The EasySolar 24/1600/40-16 MPPT 100/50 is an integrated energy solution for 24-V battery systems. It combines a true sine wave inverter, a grid and generator charger, a SmartSolar MPPT 100/50, and a pre-installed 230-V distribution system all in a single enclosure.
This reduces the amount of wiring required compared to using several individual devices. Solar power, shore power, or a generator can charge the service battery. If there is no AC power source, the inverter provides up to 1,300 W continuous power at 25 °C Ready.
The Main Benefits
- All-in-one design: Inverter, AC charger, MPPT solar charge controller, and AC distribution—all in one unit.
- Pure Sine Wave: 1600 VA or 1300 W continuous power at 25 °C and 3000 W peak power.
- High PV output: Up to 1,400 W of rated PV power on the 24-V battery system.
- Two charging sources: Charging via solar power, the utility grid, or a generator.
- PowerAssist: The inverter can supplement a limited grid or generator source during peak loads.
- Pre-configured AC distribution: An RCD and four fused 230-V outputs are built in.
Solar Power and Battery Charging
The SmartSolar MPPT 100/50 handles a maximum PV open-circuit voltage of 100 V and delivers up to 50 A of solar charging current. For the 24-V version, Victron specifies a nominal PV power of 1,400 W. Up to three PV strings can be connected via three pairs of MC4 connectors.
When grid or generator power is available, the integrated MultiPlus Compact charges the service battery at a rate of up to 40 A at 25 °C. The multi-stage adaptive charging algorithm must be compatible with the type of battery used and its permissible voltages.
4-A output for the starter battery
A separate connection can power a 24-V starter battery with up to 4 A Recharge. This trickle charger is designed as a trickle or trickle-charge output and features No dedicated charging curve. It does not replace a separate, freely programmable starter battery charger.
230-V Power Supply and PowerAssist
The sine-wave inverter delivers 230 V AC with 1,600 VA or 1,300 W continuous power at 25 °C. At 40 °C, 1,200 W is available; up to 3,000 W is possible for short periods. For devices with high inrush currents, the actual starting power must be checked on a case-by-case basis.
The 16-A transfer switch handles the switchover when an AC source is connected. PowerControl limits the load on the external source, while PowerAssist can provide additional inverter power from the battery during brief periods of higher demand. This feature requires proper system configuration.
Integrated AC Distribution
The AC power distribution system includes a 30 mA / 16 A RCD and four AC outputs, protected by two 10-A and two 16-A circuit breakers. One of the 16-A outputs is activated only when mains or generator power is present at the AC input. It is therefore suitable for loads that are not to be powered by the battery.
Suitable Applications
The EasySolar is suitable for applications that combine a 24-V battery system, solar power, and a compact 230-V distribution system:
- Boats and yachts with a 24-volt service battery
- Tiny houses and larger mobile power systems with a 24-V battery bank
- Off-grid systems in allotment gardens, hunting cabins, mountain pastures, or alpine huts
- Off-grid systems with a connection to the utility grid or a generator as an additional charging source
The connected loads must fall within the continuous and peak power ratings. For pumps, compressors, cooking appliances, or other loads with high inrush current, an individual power test is required.
Planning and Compatibility
The battery must be compatible with the system voltage of 24 V, the maximum charging current, and the planned load. For the PV array, the maximum open-circuit voltage of 100 V must be maintained under all conditions. In particular, the increase in voltage at low temperatures must be taken into account in the design. For the MPPT controller to start, the PV voltage must reach at least the battery voltage plus 5 V; thereafter, it must reach at least the battery voltage plus 1 V.
The inverter/charger features VE.Bus, while the SmartSolar controller features VE.Direct. Depending on the desired configuration and monitoring, appropriate interfaces or GX components may be required separately. The programmable relay can be configured for alarm or generator start functions, among other things.
Technical Specifications
| Article | EasySolar 24/1600/40-16 MPPT 100/50 |
| Manufacturer Part Number | CEP242161010 |
| Battery System | 24 V |
| DC Input Voltage | 19 to 33 V DC |
| Inverter | 1600 VA / 1300 W at 25 °C |
| Continuous power at 40 °C | 1,200 W |
| Top Performance | 3,000 W |
| AC Transfer Switch | 16 A |
| AC Input | 187 to 265 V AC, 45 to 65 Hz |
| Charging Current for the Service Battery | 40 A at 25 °C |
| Starting Battery Output | 24 V / 4 A, without its own charging curve |
| Solar Charge Controller | SmartSolar MPPT 100/50 |
| Maximum Solar Charging Current | 50 A |
| Nominal PV Power | 1,400 W |
| Maximum PV open-circuit voltage | 100 V |
| PV Connections | Three MC4 sets for up to three PV strings |
| AC Distribution | FI/RCD 30 mA / 16 A; two 10-A and two 16-A circuit breakers |
| Interfaces | VE.Bus and VE.Direct |
| Protection Class | IP21 |
| Dimensions | 745 × 214 × 110 mm |
| EAN | 8719076065029 |
Conclusion
The EasySolar 24/1600/40-16 MPPT 100/50 combines the key components of a 24-V solar system into a single, easy-to-manage system. It is particularly useful when higher PV output, multiple charging sources, integrated AC distribution, and a configurable Victron solution are required. The correct sizing of the battery, PV array, and loads, as well as proper programming for the specific battery type, are crucial.
Frequently Asked Questions About the EasySolar 24/1600/40-16 MPPT 100/50
-
Can the EasySolar be powered by lithium batteries?
Yes, a suitable lithium or LiFePO4 battery can be used. However, before putting the device into service, you must Charging voltages, charging current, and other charging parameters be programmed to match the battery. In addition, the battery manufacturer's specifications, as well as the required BMS and protection concept, must be observed.
-
How does the starter battery charge?
The separate output provides up to 24 V / 4 A For recharging a 24-V starter battery. The output does not have its own charging curve and is not a substitute for a separate programmable charger.
-
How many solar panels can be connected?
The electrical specifications of the PV array are the determining factor, not just the number of modules. The nominal PV power is 1,400 W, with a maximum PV open-circuit voltage of 100 V. Up to three PV strings can be connected via the three pairs of MC4 connectors.
-
Does the device deliver 1,600 W of continuous power?
No. 1600 VA is the apparent power. Victron specifies 1,300 W continuous power at 25 °C, 1,200 W at 40 °C and 3,000 W peak power.
-
What is already included in the AC distribution?
It features a built-in 30 mA / 16 A FI/RCD and four fused AC outputs. Two outputs are protected at 10 A, and two at 16 A. One of the 16-A outputs is active only when an external AC source is connected to the AC input.
Data sheet
- Input voltage
- 187-265 VAC
- Output voltage
- 230 VAC
- Battery voltage
- 24V
- Charging current
- 40A
- Loading algorithm
- multi-stage, adaptive
- Nominal PV power 24V
- 1400W
- PV input voltage
- 100V
- Connections
- MC4
- Connections
- G-ST18i
- Inverter power (25°) W
- 1300W
- Inverter power peak
- 3000W
- Transfer switch
- 16A
- Charging current Start Bat.
- Protection class IP
- IP 21
- Interface
- VE.Direct
- Interface
- VE.bus
- Cable length
- 1.5m Battery cable with ring terminals
- Cable cross-section
- 25mm2
- Feature
- AC Absicherung- FI, 16A - 10A, 10A, 16A
- Feature
- AC fuse protection- IN FI - Out FI, 16A, 16A, 10A, 10A - 16A
- Parallel / 3 phase
- YES
- Dimension
- 745 x 214 x 110mm
- Weight
- 15kg
- Max. Solar current (A)
- 50A
- PowerAssist - min. shore power
- (FW 485) - min. 2.4A
- Regenerative power supply capable (ESS) Switzerland ?
- externe Anti Insel Schaltung (ENS) notwendig
- Note
- Must be programmed for lithium batteries!
- Scope of delivery
- Temperature sensor & battery cable
- Manufacturer data sheet & operating instructions
- https://www.victronenergy.de/inverters-chargers/easysolar#datasheets
Specific References
- EAN13
- 8719076065029
- MPN