VM-3P5A Energy Meter - 3-Phase - Ve.Can - Ethernet

REL200320100

AC 3-Phase Electricity Meters via Current Transformers up to 5A

- For AC current measurement
- Industry-standard current transformers
(not included)
- 3-phase, Ethernet & Ve.CAN interface

CHF153.00
excl. VAT.
CHF165.39 incl. VAT.
favorite_border Add to wishlist

Delivery time from order approx. 10 working days
Stock: 0 Pcs.
In the inflow: 0 Pcs.

Victron Energy VM-3P5A Meter – 3-Phase Energy Meter with VE.Can & Ethernet

The Victron Energy VM-3P5A Meter is a fast and versatile energy meter for single-, two-, and three-phase AC systems. It is particularly well-suited as Grid Meters in Victron ESS Systems, but it can also be used to measure PV inverters, generators, and individual AC loads.

The measured values are displayed at a high refresh rate of 100 ms recorded and via VE.Can or Ethernet transmitted to a compatible Victron GX device. This makes the VM-3P5A ideal for applications that require fast and precise power control.

Victron VM-3P5A as a grid meter in the ESS

In a Victron Energy With the Storage System, the VM-3P5A can be used as a network meter. It records the current Grid Connection and Grid Feed-in and makes these values available to the Victron system.

Measurements are taken per phase. This allows the energy flow in single-phase, split-phase, and three-phase installations to be precisely recorded and analyzed.

VE.Can and Ethernet Integrated

The Victron Energy The VM-3P5A meter offers several communication options:

  • VE.Can: Two RJ45 ports for direct connection to a compatible Victron GX device.
  • Ethernet: An RJ45 Ethernet port for connecting to the local network.
  • Modbus UDP: Communication via Ethernet.

The energy meter can, for example, be connected to a Cerbo GX or Ekrano GX can be connected. The measured values can then be viewed on the GX device as well as in the Victron VRM Portal be monitored.

Flexible Applications

Depending on the system configuration, the Victron VM-3P5A can be used for various measurement tasks:

  • Grid Meters in Victron ESS Systems
  • Measuring Grid Consumption and Grid Feed-in
  • Measurement of PV Inverters
  • Measurement of AC Generators
  • Measuring Individual AC Loads
  • Monitoring of EV Charging Stations
  • Monitoring Heat Pumps

External 5-A current transformers

Current is measured via External current transformers with a secondary current of 5 A. This allows the VM-3P5A to be flexibly adapted to systems of various sizes.

Important: The required current transformers are not included with the VM-3P5A and must be selected separately to suit the specific installation.

The information 5 A refers to the secondary current of the current transformer and not to the maximum measurable load or system current.

Measurements and Functions

The Victron VM-3P5A provides a wide range of electrical measurement and diagnostic values. These include, among others:

  • Phase-to-Neutral Voltage
  • Phase-to-Phase Voltage
  • Phase Flows
  • Neutral Current
  • Power per phase
  • Power Factor
  • Phase Sequence in Three-Phase Systems
  • Warning for Incorrect Phase Rotation
  • Protective Grounding Voltages

In addition, the status LED can be configured as an energy pulse signal. Depending on the application, various calculation methods are available for energy measurement.


Technical Specifications Victron Energy VM-3P5A Meter

Manufacturer Victron Energy
Model VM-3P5A
Manufacturer Part Number REL200320100
Phases Single-phase / Split-phase / 3-phase
L-N Input Voltage 85–265 VAC
Input Voltage L-L 150–460 VAC
Frequency 50 / 60 Hz
Current Measurement Via external current transformers
Current Transformer Secondary Current 5 A
VE.Can 2 × RJ45
Ethernet 1 × RJ45
Ethernet Protocol Modbus UDP
Refresh rate 100 ms
Power Supply Self-supply via N-L1-L2-L3
Power Consumption 1.85 W / 3.5 VA
Protection Class IP20
Operating Temperature -10 to +55 °C
Storage Temperature -20 to +70 °C
Relative Humidity < 90%, non-condensing
Max. operating height 2,000 m
Surge Category CAT III
Housing Polycarbonate
Dimensions (H × W × D) 90 × 71 × 59 mm
Weight 260 g
Standard EN-IEC 61010-1

What's Included

  • 1 × Victron Energy VM-3P5A Meter
  • Input Terminal Blocks
  • 2 × VE.Can RJ45 terminating resistors
Note: Current transformers are not included.

Frequently Asked Questions About the Victron VM-3P5A

  • What is the Victron VM-3P5A used for?


    The Victron VM-3P5A is used to measure power and energy in AC systems. It is particularly often used as Grid Meters in Victron ESS Systems used. However, it can also measure PV inverters, generators, and individual AC loads.

  • Can the Victron VM-3P5A measure three-phase power?


    Yes. The VM-3P5A supports single-phase, split-phase, and three-phase systems. This allows it to be used in a variety of system configurations.

  • Are the current transformers included in the scope of delivery?


    No. The Victron VM-3P5A requires external current transformers with 5 A secondary current. These must be selected and ordered separately to suit the specific installation.

  • Does "5 A" mean that the VM-3P5A can only measure up to 5 A?


    No. The 5 A refers to the Secondary current of the current transformers used. The actual measurable system current depends on the turns ratio of the current transformer used.

  • Can the VM-3P5A be connected via Ethernet?


    Yes. The energy meter has an RJ45 Ethernet port and supports Ethernet Modbus UDP. Alternatively, communication can take place via VE.Can.

  • Is the VM-3P5A compatible with a Cerbo GX?


    Yes. The VM-3P5A can be connected via VE.Can or Ethernet can be connected to a compatible Victron GX device, such as the Cerbo GX.

  • Can I view the readings in the Victron VRM Portal?


    Yes. If the VM-3P5A is integrated into a Victron system with a GX unit, the measured values can be accessed via the Victron VRM Portal can be monitored and analyzed remotely.

  • Can the VM-3P5A also measure a PV inverter?


    Yes. In addition to being used as a utility meter, the VM-3P5A can also be used to measure a PV inverter, generator, or an individual AC load circuit be used.

REL200320100

Data sheet

Frequency
50 & 60 Hz
Amperage
Energiemeter, 3x Stromwandler, 2x Ve.CAN Abschlusswiederstände
Amperage
Connections
0.25-1.5 mm2 - Plug-in screw terminals
Feature
3 Phasen
Feature
Transmission rate 100sm
Dimension
90 x 71 x 59 mm
Note
3 phases
Scope of delivery
Strommessung via klickbare Stromwandler
Manufacturer data sheet & operating instructions
https://www.victronenergy.de/meters-and-sensors/energy-meter#downloads-datasheets
System voltage
230VAC

Specific References

EAN13
8719076072539
MPN
REL200320100

You might also like

Customers who bought this product also bought: