Featured products
Multi HS19 Solar 15 kW
Inverter, Charger & MPPT Solar Charger 48V 15,000VA
- 4 MPPT solar trackers (8 kW each), 15 kW 3-phase inverter, peak 22 kW (5 sec)
- Battery voltage: 600–1,000 V, PV voltage: 100–600 V, max. charging current: 41 A,
- max. discharge current: 25 A, 1x AC In, 2x AC Out, relay, remote, 12V In, Ve.Direct
- Vehicle CAN, Battery CAN, Bluetooth,
- 19 inches x 4U x 70 cm - 26.5 kg
Victron Multi HS19 Solar 15 kW
The Victron Multi HS19 Solar 15kW is an integrated power center for high-performance three-phase high-voltage systems. The 19-inch unit combines a bidirectional 15-kW inverter/charger with four independent high-voltage MPPT trackers. This reduces the number of individual components, connections, and rack space required.
The Multi HS19 Solar operates with compatible, BMS-controlled high-voltage batteries ranging from 650 to 1,000 V. It provides 400 V three-phase alternating current, charges the storage system from PV or a suitable AC source, and can supply stored energy to loads, optimize self-consumption, or serve as a backup.
The Main Benefits
- 15 kW true three-phase power: A single unit supplies a 400-V three-phase system with up to 15 kW of continuous power at ambient temperatures of up to 40 °C.
- Four independent MPPT trackers: Four separate PV strings, each with a capacity of up to 8 kW, enable a maximum total PV output of 32 kW.
- High-Voltage Battery System: The operating range of 650 to 1,000 V reduces battery current while maintaining the same power output and allows for more compact DC cables.
- PowerControl and PowerAssist: The device can limit the power drawn from the AC input and briefly supplement it with battery power if the load exceeds the available mains power.
- High efficiency: Conversion losses are reduced by up to 98% in the inverter and up to 99% in the MPPT trackers.
- 19-inch System Integration: The 4-HE unit can be installed in an energy center along with compatible rack batteries and other system components.
Four MPPT trackers for flexible PV planning
The four independent solar inputs make it easier to divide a larger PV system across different orientations or shading conditions. Each tracker processes its own PV string and delivers up to 8 kW under the specified conditions. The maximum total output is 32 kW.
The MPPT operating range is from 100 to 600 V DC. If the device is started using only solar energy, at least 300 V is required to wake up the communication system. The MPP current is limited to 13.5 A and the short-circuit current to 20 A per string.
For self-consumption, peak shaving, backup, and off-grid use
In an energy storage system, the Multi HS19 Solar can store solar power, increase self-consumption, and cover peak loads with energy from the battery. PowerControl prioritizes the connected loads and limits the current at the AC input. PowerAssist provides additional battery power during short-term spikes in demand.
In the event of a power outage, AC-out-1 can continue to be powered by the battery and PV system. This makes the device suitable for professionally designed backup solutions with three-phase critical loads. In off-grid systems, it connects high-voltage storage systems, a PV system, and a 400-V distribution network.
Suitable applications include large residential energy systems, agricultural and commercial facilities, stationary power containers, and sites with peak shaving or backup power needs. Suitability depends on the load profile, battery, PV system design, grid connection, and applicable installation regulations.
Compatible High-Voltage Batteries
The Multi HS19 Solar uses the battery management system's CAN communication to obtain permissible charge and discharge limits. It therefore works only with high-voltage batteries that support the Victron HV protocol and are listed on the current Victron compatibility list for the Multi HS19.
Victron recommends connecting the battery BMS to a GX device via BMS-CAN. A direct CAN connection to the Multi HS19 is technically possible, but does not offer the same range of functions. In addition, the specific number of modules or stack configuration must fall within the usable voltage range specified by Victron for the respective battery system.
Power and Energy Flow
The inverter delivers up to 15 kW of continuous output power at temperatures up to 40 °C and 22 kW of peak power for 5 seconds. The maximum continuous AC current is 22 A RMS per phase. The maximum AC input and through-current is 32 A.
On the battery side, the maximum discharge current is 25 A and the maximum charge current is 41 A. At 800 V, the maximum charging current corresponds to a charging power of up to approximately 33 kW. If the inverter and solar controller are operated simultaneously at full power, the device may reduce the PV output and, under higher thermal loads, also reduce the inverter output.
Monitoring and Victron System Integration
The built-in display shows AC input, AC outputs, battery parameters, and the output of each individual MPPT tracker. Bluetooth and VictronConnect are used for local configuration and status monitoring.
A GX device can be integrated via VE.Can for central system monitoring, data logging, and access to the VRM portal. Battery CAN is intended for communication with the battery BMS. VE.Direct can be used with a GlobalLink 520 or a VE.Direct-zu-USB-Adapter be used.
An optional 12-V input can keep the electronics active and support a cold start. Although the device can operate without this auxiliary voltage, it may lose communication if no other power source is available, which can limit its ability to perform a cold start.
AC Outputs and Power Connection
The Multi HS19 Solar has a three-phase AC input and two three-phase AC outputs. AC-out-1 remains active during battery operation. If a valid AC source is available at the input, both AC outputs are active. This allows critical and non-critical loads to be planned separately.
Technical Specifications
| Product | Victron Multi HS19 Solar 15k |
| Item Number | PMR803150300 |
| AC System | 400 V AC ± 10%, three-phase; L1, L2, L3, N, PE |
| Rated / Continuous Power | 15 kVA / 15 kW up to 40 °C |
| Top Performance | 22 kW for 5 seconds |
| Continuous current per phase | 22 A RMS |
| AC Input / Through Current | Maximum 32 A |
| AC Inputs / AC Outputs | 1 / 2 |
| Inverter Efficiency | A maximum of 98% |
| Idle Power | 50 W at 650 V battery voltage |
| Battery voltage range | 650 to 1,000 V DC |
| Maximum Battery Charge/Discharge Current | 41 A / 25 A |
| Battery Communication | CAN; Battery with Victron HV protocol and current approval required |
| MPPT Trackers / PV Strings | 4 / 4 |
| PV Capacity | Maximum 8 kW per string / 32 kW total |
| MPPT Range / Wake-up Voltage | 100 to 600 V DC / at least 300 V |
| Maximum PV open-circuit voltage | 600 V DC |
| MPP / Short-Circuit Current per String | Maximum 13.5 A / 20 A |
| MPPT Efficiency | A maximum of 99% |
| Communication | Battery CAN, VE.Can, VE.Direct, Bluetooth |
| Parallel Operation | Not currently supported |
| Operating Temperature | 0 to +60 °C; full rated power up to 40 °C |
| Protection Class / Environment | IP20 / air-conditioned indoor environment |
| Rack Dimensions / Depth | 19 inches, 4U / approx. 70 cm |
| Weight | 26.5 kg |
Planning and High-Voltage Installation
The Multi HS19 Solar is designed for installation in a non-flammable standard 19-inch rack in a protected, air-conditioned indoor environment. For cooling, Victron recommends at least 1U of clearance above and below the unit, as well as unobstructed airflow from front to back.
The battery, PV inputs, and AC side are not electrically isolated from one another. Even when the device is turned off, voltages of up to 1,000 V DC may be present internally. Therefore, design, installation, commissioning, and maintenance must be performed exclusively by qualified professionals trained in high-voltage direct current, in accordance with the manufacturer’s documentation and local regulations.
Conclusion
The Victron Multi HS19 Solar 15kW combines 15 kW of three-phase power, four high-voltage MPPT trackers, and connectivity to regulated 650- to 1000-V batteries in a compact rack-mounted unit. This makes it a powerful platform for professional self-consumption, peak-shaving, backup, and off-grid systems. As a Victron distributor, AUTARKING provides support with compatibility testing, system design, and integration.
Frequently Asked Questions About the Victron Multi HS19 Solar 15kW
-
Can the Multi HS19 Solar be powered by a 48-V battery?
No. The Multi HS19 Solar is intended exclusively for Compatible high-voltage battery systems ranging from 650 to 1,000 V required. The battery must communicate via CAN and be approved by Victron for use with the Multi HS19.
-
Which high-voltage batteries are compatible?
Only models and stack configurations from the current Victron list “HV Battery Compatibility – Multi HS19” may be used. Since this list is subject to expansion or change, specific approval must be verified immediately prior to planning and ordering.
-
Does a single Multi HS19 Solar unit produce true three-phase power?
Yes. A device provides 400 V AC, three-phase with up to 15 kW of continuous power and 22 A RMS per phase. Three separate inverters are not required.
-
Can multiple Multi HS19 Solar units be operated in parallel?
No. The current hardware and firmware do not support connecting multiple devices in parallel. Victron notes that future hardware versions may support this feature; however, this does not constitute a guarantee for the device in question.
-
Can a generator currently be used as an AC power source?
According to the current Victron manual, generator operation Not yet supported. Although the existing programmable relay can technically be configured for start/stop signals, this does not automatically make the AC input compatible with a generator.
-
Is 32 kW of PV power permanently available at the same time as 15 kW of AC power?
32 kW is the maximum total PV output under the specified conditions. If the inverter and solar controller are operating at full power simultaneously, thermal power management may first reduce the PV output and, under heavier loads, also reduce the inverter output.
-
Is the Multi HS19 Solar approved for grid connection in Switzerland?
This should not be determined solely based on a selectable grid code. Before feeding power into the grid, you must verify the current Victron certificates, the requirements of the relevant distribution system operator, and the Swiss installation requirements.
-
Who is authorized to install the Multi HS19 Solar?
Due to battery voltages of up to 1,000 V DC, the lack of galvanic isolation, and the potential for life-threatening DC arcing, the system may only be designed, installed, commissioned, and maintained by appropriately qualified high-voltage specialists.
Data sheet
- Input voltage
- 400Vac ± 10%, 3-phase
- Output voltage
- 400Vac ± 10%, 3-phase
- Frequency
- 45-65 Hz
- Battery voltage
- 650 - 1000V
- Charging current
- Loading algorithm
- multi-stage, adaptive
- PV input voltage
- 300V max. 450V
- Connections
- MC4
- Connections
- DC 5.7mm Surlok / AC Push-in spring connectors
- Number of outputs
- 2
- Inverter power peak
- 25kW (5 sek)
- Transfer switch
- 31A
- Protection class IP
- IP 20
- Interface
- VE.CAN & VE.Direct & Bluetooth
- Parallel / 3 phase
- 3Phase Yes / Parallel No
- Dimension
- 425 x 440 x 125mm
- Weight
- 11kg
- Number of strings
- 2 String 1 Tracker
- Regenerative power supply capable (ESS) Switzerland ?
- Not yet
- Note
- Generator operation is not yet supported
- Manufacturer data sheet & operating instructions
- Generatorbetrieb wird noch nicht unterstützt
- PV Leistung
- 4 MPPT Tracker à 8kW (32kW total)
- Wechselrichterleistung bis 40°
- 15kW
Specific References
- EAN13
- 8719076058410
- MPN
- PMR803150300